Commercial buildings face requirements from OCFA, Cal/OSHA, SCAQMD, and IRWD.

⚠️ Orange County uses 55-foot high-rise threshold — lower than most CA cities (75ft)

Example: A 12-story, 195,000 sq ft Spectrum office has 14 requirements. Previewing 6.

Commercial Office

000 California Street, Irvine, CA

Irvine, CA

Required Filings

Fire & Life Safety

Orange County Fire Authority High-Rise Inspection

Orange County Fire Authority (OCFA)

CA H&S Code 13217 / OC Fire Code

Required: Annual high-rise inspection by OCFA including fire command center, ERCES, smoke control, and emergency systems

Deadline

Annual inspection by OCFA

Penalty

Violations; fines; potential closure order

⚠ Why: IMPORTANT: Orange County uses 55-foot high-rise threshold (not 75ft). Buildings 55+ feet require annual OCFA inspection per CA H&S Code 13217.

Evidence Required:

  • OCFA inspection report
  • Fire pump test certificate
  • ERCES certification
  • Smoke control test records
Fire & Life Safety

OCFA Fire Alarm System Inspection

Orange County Fire Authority (OCFA)

CFC 901.6.1 / NFPA 72

Required: Annual fire alarm system inspection, testing, and maintenance by licensed contractor; maintain documentation for OCFA review

Deadline

Annually from date of last inspection

Penalty

Violations; fines; system red-tag

⚠ Why: California Fire Code and NFPA 72 require annual fire alarm system inspection and testing. OCFA verifies compliance during building inspections.

Evidence Required:

  • Fire alarm inspection report (NFPA 72 compliant)
  • Contractor license verification (C-10)
  • Deficiency correction records
Fire & Life Safety

OCFA Fire Sprinkler System Inspection

Orange County Fire Authority (OCFA)

NFPA 25 / Orange County Fire Code

Required: Annual sprinkler inspection; 5-year internal pipe inspection; quarterly valve checks

Deadline

Annual inspection; 5-year internal

Penalty

Violations; insurance issues; liability

⚠ Why: NFPA 25 and California Fire Code require regular inspection and testing. OCFA verifies during annual inspections.

Evidence Required:

  • Annual sprinkler inspection report
  • 5-year internal inspection
  • ITM records
  • Valve position logs